INTERFACE CARDS FOR PERSONAL COMPUTERS
DAQ-16
Data Acquisition Adapter
for 16-bit ISA compatible machines
Users Manual
OMEGA ENGINEERING, INC. TEL: (203) 359-1660
One Omega Drive FAX: (203) 359-7700
P.O. Box 4047 Toll free: 1-800-826-6342
Stamford, CT 06907-4047 E-mail: [email protected]
htt
p
://www.dasieee.com
Vedere la pagina 0
1 2 3 4 5 6 ... 29 30

Sommario

Pagina 1 - Users Manual

INTERFACE CARDS FOR PERSONAL COMPUTERSDAQ-16Data Acquisition Adapterfor 16-bit ISA compatible machinesUsers ManualOMEGA ENGINEERING, INC. TEL: (2

Pagina 2 - RETURN REQUESTS/INQUIRIES

2. Circuit Board Description and ConfigurationThe base address of the DAQ-16 is selected using switches SW1 and SW2. The operatingmode of the DAQ-1

Pagina 3 - http://www.omega.com

Figures 2-1 and 2-2 show the configuration options for jumpers J7 and J6.J7J7 J7132424241313 Gain = 1 Gain = 10 Gain

Pagina 4

The final stage of the A/D converter circuit is the A/D converter IC. The converter must beconfigured for unipolar or bipolar input voltages and for b

Pagina 5 - Declaration of Conformity

+32,767+32,767+65,535+65,535+Vmax+16,3840+49,152+32,768+Vmax/20-32,768+32,76800-16,384n/a+16,384n/a-Vmax/2-32,768n/a0n/a-Vmaxbipolarunipolarbipolaruni

Pagina 6 - 1. Introduction

2.2 Digital to Analog ConvertersThe digital to analog (D/A) section of the DAQ-16 consists of two independent 12-bitmultiplying D/A converters, and tw

Pagina 7 - List of Figures and Tables

5 6 7 81 2 3 4J4Channel 1 gainChannel 1 selectChannel 0 selectChannel 0 gainFigure 2-5. Jumper J4 ConfigurationTable 2-3 lists confi

Pagina 8

2.4 Base AddressThe DAQ-16 uses 16 consecutive I/O address locations in the range 0 to 0FFFFH. Twosix-position switches (SW1 and SW2) are us

Pagina 9 - 1.2 DAQ-16 Specifications

2.5 Clock SelectionThe DAQ-16 is equipped with a programmable clock circuit to produce data sampling ratesindependent from the clock rate of the host

Pagina 10

2.5.1 Internal ClockSampling rates for the internal clock can be calculated using the following equation: t = 100ns * [N1*N2] o

Pagina 11

When configured for a 48-bit divider, the first sampling period will be slightly longer thanthe others because the first clock period is required to

Pagina 12

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC., warrants this unit to be free of defects in materials and workmanship for a period of 13months from the da

Pagina 13

When the multi-function timer is used as a pre-divider, the frequency of the external clockinput may be varied from DC to 10 MHz as long as the high p

Pagina 14

2.7 Direct Memory AccessDirect Memory Access (DMA) transfers provide a way of transferring data from theDAQ-16's A/D converter into the compute

Pagina 15 - 2.3 Digital Input/Output

2.8 InterruptsThe DAQ-16 is capable of generating an interrupt from one of four sources:1. End of conversion signal2. DMA terminal count3. Multi-funct

Pagina 16 - 2.4 Base Address

3. External ConnectionsThe DAQ-16 is equipped with a high density 62-pin connector as shown in Figure 3-1.2 - CH1+ 4 - CH2-6 - CH4+8 - C

Pagina 17 - 2.5 Clock Selection

CH0-,CH0+,...,CH7-,CH7+ : Analog inputs to the analog to digital converter. Amplitude andpolarity depend upon jumper settings. The input resista

Pagina 18

4. Register Description and ProgrammingThe DAQ-16 uses 16 consecutive I/O address locations in the range 0 to FFFFH. The cardutilizes these addresse

Pagina 19

DMAEN - enables / disables DMA. When set, logic 1, DMA transfers are enabled. DMACT - enables the multi-channel DMA capability of the DAQ-16. When set

Pagina 20 - 2.6 Trigger Selection

4.1.2 Start of Conversion RegisterThe start of conversion register is 16-bit write only and performs two functions:1. When configured for internal

Pagina 21 - 2.7 Direct Memory Access

4.2 Programming the 8254 Counter/TimerThis section provides programming information for the 8254 counter/timer as implementedon the DAQ-16. For more

Pagina 22 - Factory default = IRQ 5

Counter 1 - Clock rate register (high word)operating mode: 2minimum count value: 2configuration byte: 0 / 1 / 1 / 1 / 0 / 1 / 0 / 0 = 74H

Pagina 23 - 3. External Connections

OMEGAnet On-line Service: Internet e-mail: http://www.omega.com [email protected] North Americ

Pagina 24

DAQ-16 Users ManualVersion 2.20January 28, 1999Part No. 940-0032-220

Pagina 25 - 4.1 Register Description

United Kingdom: One Omega Drive, River Bend Technology DriveISO 9002 CertifiedNorthbank, Irlam, ManchesterM44 5EX, England Tel: 44 (161) 777-6611FAX:

Pagina 26

Declaration of ConformityManufacturer's Name: Omega Engineering Inc.Manufacturer's Address: One Omega DriveStamford, CT 06907-0047Applicati

Pagina 27

Table of Contents284.2 Programming the 8254 Counter/Timer...274.1.8 8254 Control Word/Status Register...

Pagina 28

List of Figures and Tables25Table 4-1. DAQ-16 Address Map...15Table 2-3. Jumper J4 Configuration.

Pagina 29

1. IntroductionThe DAQ-16 is a high speed data acquisition adapter for IBM AT compatible machinesoffering eight differential analog input channels wi

Pagina 30 - Part No. 940-0032-220

1.2 DAQ-16 SpecificationsDACK 5, 6, 7DRQ 5, 6, 7DMA Levels:IRQ 2, 3, 4. 5, 6, 7, 10, 11, 12, 14, 15Interrupt Levels:0000H - FFFFHI/O Address Range:ISA